Welcome to Open Science
Contact Us
Home Books Journals Submission Open Science Join Us News
The Design on Power Supply of ACFM Test System Based on AD9959 Chip
Current Issue
Volume 4, 2017
Issue 1 (January)
Pages: 1-5   |   Vol. 4, No. 1, January 2017   |   Follow on         
Paper in PDF Downloads: 76   Since Aug. 17, 2017 Views: 1514   Since Aug. 17, 2017
Authors
[1]
Ren Shangkun, Key Laboratory of Nondestructive Testing of Ministry of Education, Nanchang Hangkong University, Nanchang, China.
[2]
Hu Jiang, Key Laboratory of Nondestructive Testing of Ministry of Education, Nanchang Hangkong University, Nanchang, China.
[3]
Zhou Liuci, Key Laboratory of Nondestructive Testing of Ministry of Education, Nanchang Hangkong University, Nanchang, China.
Abstract
The sine wave signal excitation source of meeting the requirements of ACFM was designed. This circuit are composed of direct digital synthesizer, low-pass filters, programmable amplifier and power amplifier. The design idea overcame the shortage that frequency and voltage were uncontrollable in the ACFM traditional detection systems before. It proved that the circuit can realize the objective as follows: the excitation’s frequency and voltage are stable and controllable; The output current is strong enough; The signal to noise ratio is high enough. This design are completely satisfied to the ACFM system’ requirement
Keywords
Nondestructive, ACFM, Test Systrm, AD9959, Driving Source
Reference
[1]
Saguy H. Flaw detection in metals by the ACPD technique: Theory and experiments. NDT and E, International, 2007, 40 (7): 505-509.
[2]
Low C K. Defect evaluation using the alternating current field measurement technique Non-Destructive Testing and Condition Monitoring, 2004, 46 (10): 598-605.
[3]
Knight M. J, et al. Effect of residual stress on ACFM crack measurements in drill collar threaded connections. NDT&E International, 2004, 37 (5): 337-343.
[4]
R. F. Mostafavi. Analysis technique for interaction of high-frequency rhombic inducer field with cracks in metals [J], IEEE Trans. Magn, 1997, 33: 2291-2298.
[5]
Mirshekar-Syahkal D, 1-D probe array for ACFM inspection of large metal plates. IEEE Transactions on instrumentation and measurement, 2002 51 (2): 374-382.
[6]
Rollo Jarvis, Peter Cawley, Peter B. Nagy. Performance evaluation of a magnetic field measurement NDE technique using a model assisted Probability of Detection framework. NDT and E International, 91 (2017) 61-70.
[7]
Wei Li, Xin an Yuan, Guoming Chen, Xiaokang Yin, Jiuhao Ge. A feed-through ACFM probe with sensor array for pipe string cracks inspection. NDT&E International 67 (2014) 17-23.
[8]
Li Wei Chen Guo ming, Yin Xiao kang, Zhang Chuan rong, Liu Tao. Analysis of the lift-off effect of a U-shaped ACFM system. NDT&E International 53 (2013) 31-35.
[9]
G. L. Nicholson, A. G. Kostryzhev, X. J. Hao, C. L. Davis. Modeling and experimental measurements of idealized and light-moderate RCF cracks in rails using an ACFM sensor. NDT & E International, 2011, 44: 427-437.
[10]
M. Ph. Papaelias, M. C. Lugg, C. Roberts, C. L. Davis. High-speed inspection of rails using ACFM techniques. NDT & E International, 2009, 42: 328-335.
[11]
Li Bing. Development and test of the AC field detection instruments [D]: Nan Chang Hang Kong University, 2013.
[12]
Ren Shangkun, Zhu Zhibin, Lin Tianhua, Song Kai, Ren Jilin. Design for the ACFM Sensor and the Signal Processing Based on Wavelet Denoise. 2009 2nd International Congress on Image and Signal Processing (CISP'09), Pressed by IEEE.
[13]
J. M. Chacón Muñz, F. P. García Márquez, M. Papaelias. Railroad inspection based on ACFM employing a non-uniform B-spline approach. Mechanical Systems and Signal Processing 40 (2013): 605-617.
[14]
M. Ph. Papaelias, M. C. Lugg, C. Roberts, C. L. Davis. High-speed inspection of rails using ACFM techniques. NDT&E International 42 (2009) 328-335.
[15]
Smith M. The detection of pipeline SCC flaws using the ACFM technique [J], Non-Destructive Testing and Condition Monitoring 2005, 47 (12): 765-768.
[16]
Raine A. The use of alternating current field measurement (ACFM) array technology in the power generation industry Non-Destructive Testing and Condition Monitoring, 2002, 44 (9): 557-560.
[17]
Li Wei, Chen Guo-ming, Qi Yu-liang. Study on the Inversion Algorithm of Crack-sizing Based on the Alternating Current Field Measurement China Mechanical Engineering, 2007, 18 (1): 13: 34.
[18]
Chen Guo-ming, Li Wei, Wang Ze-xin. Structural optimization of 2-D array probe for alternating current field measurement [J]. NDT & E International, 2007, 40: 455–461.
[19]
Chen Jia Jia, Pan Zhi Hao, Wang Tian Lin. A High Accurate Signal Generator Based on DDS Chip AD9959 [J]. Process Automation Instrumentation, 2007, 28 (4): 50-53.
[20]
Peng Bo, Wu Xue Jie. Design of Multi-channel Signal Generator Based on AD9959 [J]. Industrial control computer, 2012, 25 (8): 20-21.
[21]
OPA564 Data Sheet. Texas Instruments. lnc, 2013.
Open Science Scholarly Journals
Open Science is a peer-reviewed platform, the journals of which cover a wide range of academic disciplines and serve the world's research and scholarly communities. Upon acceptance, Open Science Journals will be immediately and permanently free for everyone to read and download.
CONTACT US
Office Address:
228 Park Ave., S#45956, New York, NY 10003
Phone: +(001)(347)535 0661
E-mail:
LET'S GET IN TOUCH
Name
E-mail
Subject
Message
SEND MASSAGE
Copyright © 2013-, Open Science Publishers - All Rights Reserved